ESD antistatic chairs — work chairs compliant with EN 61340-5-1, dissipating electrostatic charges to earth. For assembly workstations for electronics, PCBs, semiconductors, EPA zones and ATEX areas. PUR seat with graphite additive (surface resistance 10⁶-10⁹ Ω), conductive base with TÜV approval, antistatic castors. Low versions (for 850 mm ESD tables) and high versions (up to 1100 mm). See also PUR chairs (non-ESD) and workshop chairs. Made in Poland, 5-year warranty.
List of products
What is an ESD chair and when is it required?
An ESD chair (Electrostatic Discharge) is a work chair that dissipates electrostatic charges accumulated in the worker's body to earth. Required in environments where an ESD discharge could damage electronics (microprocessors, integrated circuits, PCBs) or pose an ignition risk (ATEX zones with flammable gases/dusts). The industry standard is defined by EN 61340-5-1 and ANSI/ESD S20.20.
ESD chairs are mandatory equipment in: PCB (printed circuit board) assembly, semiconductor production, electronic component warehouses, electronics repair services, measurement laboratories, cleanrooms, EPA zones (ESD Protected Area), ATEX zones (where there is a risk of explosion).
ESD chair vs standard PUR chair — the differences
| Feature | ESD chair | PUR chair (standard) |
|---|---|---|
| Seat material | PUR with graphite additive (conductive) | Standard PUR (insulator) |
| Surface resistance | 10⁶-10⁹ Ω (conductive) | 10¹² Ω+ (insulator) |
| Base | Conductive, connected to conductive castors | Standard painted steel |
| Castors | Antistatic (conduct to the ESD floor) | Standard rubber |
| Certificate | EN 61340-5-1, ANSI/ESD S20.20 | TÜV, standard OHS |
| Price | ~30-50% more expensive | Standard |
ESD chair versions — low, high, office
- Low ESD chairs (seat 420-550 mm) — for standard 850-900 mm ESD assembly tables. The most popular version for PCB workstations.
- High ESD chairs (seat 600-800 mm + footrest) — for high 1000-1100 mm assembly tables, where the worker looks down on the part from above (precision SMD assembly).
- Ergonomic (office) ESD chairs — with an ergonomic backrest and armrests, for longer comfortable work of 8h+ (quality control rooms, technical offices in EPA zones).
- ESD stools — semi-high, for dynamic work at high ESD tables.
Who ESD chairs are for — industries
- PCB and SMD production — printed circuit board assembly, BGA soldering, AOI optical inspection
- Semiconductor production — wafer fab, packaging, testing
- Electronics servicing — repair of phones, computers, meters, medical devices
- Electronic component warehouses — packing/unpacking of chips, BGA, FPGA
- Measurement laboratories — precision meters, sensitive electronic equipment
- ATEX zones — chemical production, paint shops, solvent stores (explosion risk)
- Cleanrooms — pharmaceutical and medical production, microelectronics
Build and approvals
- Seat/backrest: PUR with graphite particles, resistance 10⁶-10⁹ Ω, material certificate
- Gas lift: class 4 gas cylinder (TÜV approval), with an earthing strip
- Base: 5-star conductive steel (not painted with insulating paint — bare or coated with conductive paint)
- Castors: antistatic (ESD marking), conductive rubber — required on an ESD floor (conductive vinyl, concrete with graphite admixture)
- Certificate: EN 61340-5-1 (Europe) or ANSI/ESD S20.20 (USA) — issued for every chair
- TÜV/GS approval load capacity 150 kg, stability 10°
- Made in Poland by Rosart and Polstein, 5-year warranty
Frequently asked questions
What does a resistance of 10⁶-10⁹ Ω mean?
It is the surface resistance range typical of dissipative materials (which disperse charge). Materials with a resistance below 10⁵ Ω are too conductive (dangerous — the full current would pass through the body), above 10¹⁰ Ω they are insulators (they accumulate charge). The 10⁶-10⁹ Ω range is ideal: slow, safe dissipation of charge to earth.
Does the floor have to be ESD for an ESD chair to work?
Yes. An ESD chair dissipates charges to the floor — if the floor is an insulator (ordinary tiles, parquet), the charges have nowhere to go. An ESD floor is required: conductive vinyl, concrete with graphite admixture, antistatic floor paint, or an ESD mat at the workstation. Chair + floor + worker's wrist strap = a complete ESD system.
Do ESD chairs require regular checks?
Yes. EN 61340-5-1 and ANSI/ESD S20.20 require periodic resistance measurements (usually once a year) — to check that the material has not lost its conductive properties (e.g. after years of cleaning or oil contamination). We supply measurement instructions or carry out measurements on request.
Can an ESD chair be cleaned with disinfectants?
Yes — the PUR seat is resistant to alcohol, IPA and water with detergent. Avoid very aggressive solvents (acetone, toluene) — they can leach graphite out of the PUR and reduce its ESD properties. Standard IPA disinfection is safe.
How long will an ESD chair last?
With 8h of intensive daily use: 5-8 years while retaining its ESD properties. After this period, a resistance measurement is recommended — if it exceeds 10⁹ Ω (too insulating), the seat or the whole chair needs replacing. The steel structure (base, gas lift) lasts 10+ years.
Related categories
| Category | What you'll find |
|---|---|
| PUR chairs (non-ESD) | Washable chairs for workshops without ESD requirements |
| Workshop chairs | Main category — all types of work chairs |
| Laboratory chairs | High chairs for 1000-1100 mm lab tables (also ESD versions) |
| Industrial stools | Stools without a backrest — also available in ESD versions |